RICOH imagine.change.Global

Environmental data:Performance data -Energy Conservation / Prevention of Global Warming-

Note

Major performance data reported for FY2012 were verified by Bureau Veritas Japan Co., Ltd., an independent certification body. Verification is offered at four levels reflecting decremental data monitoring coverage, specifically indicated by the following symbols (*1: 100%; *2: 75%-less than 100%; *3: 50%-less than 75%; *4: below 50%). Figures that lack any of these marks indicate that such data are not applicable for third-party verification.

Energy consumption

Scope of data collection: Ricoh Company, Ltd. (production and non-production sites), production subsidiaries both inside and outside Japan, non-production subsidiaries in Japan, and overseas sales subsidiaries (main sites)

  Unit Results
FY2008 FY2009 FY2010 FY2011 FY2012
Total calories TJ 3,771 3,714 4,824 4,887 5,079*2
Kerosene TJ 56 51 45 20 20
Heavy oil A TJ 116 86 574 619 658
Town gas TJ 585 524 631 647 639
Natural gas/LNG TJ 719 805 837 932 991
LPG TJ 22 24 65 59 48
Electric power purchased TJ 1,835 1,810 2,110 2,098 2,223
Steam TJ 0 0 49 48 49
Light oil TJ 44 38 64 51 56
Gasoline TJ 391 372 445 409 392
Green power certificate TJ 4 4 3 4 3
  • *Inaccuracies have been identified in the fiscal 2011 data reported in the past, and corrections have been made with the reporting of fiscal 2012 data.

Power generation

Scope of data collection: Ricoh Company Ltd. (production/non-production sites), production subsidiaries inside and outside Japan

  Unit Results
FY2008 FY2009 FY2010 FY2011 FY2012
Total power generation MWh 34,617 27,952 30,922 31,651 31,390
Off-grid power MWh 67 0 0 0 0
Solar power MWh 111 108 123 444 409
Cogeneration MWh 34,439 27,844 30,799 31,207 30,981

Greenhouse gas emissions

1. CO2 emissions by Ricoh Company, Ltd.

Scope of data collection: Ricoh Company Ltd. (production/non-production sites)

  Unit Results
FY2008 FY2009 FY2010 FY2011 FY2012
Scope1 CO2 1000t-CO2 46.8 45.6 46.0 47.4 46.8*1
5 gases (CO2 equivalent) 1000t-CO2 26.0 22.2 21.8 20.3 17.7*1
Scope2 CO2 1000t-CO2 87.5 95.0 91.6 86.5 82.7*1
Total 1000t-CO2 160.3 162.8 159.5 154.2 147.2*1
Emissions per sales unit t-CO2
/100 million yen
16.9 19.2 18.9 19.4 18.3

2. CO2 emissions by Ricoh Group

Japan

Scope of data collection: Ricoh Company, Ltd. (production/non-production sites), production subsidiaries inside Japan, non-production subsidiaries in Japan

  Unit Results
FY2008 FY2009 FY2010 FY2011 FY2012
Scope1 CO2 1000t-CO2 88.8 78.6 82.5 82.8 81.1*2
5 gases (CO2 equivalent) 1000t-CO2 28.2 23.1 22.9 21.4 18.5*1
Scope2 CO2 1000t-CO2 135.6 135.7 146.2 137.6 133.1*2
Total 1000t-CO2 252.6 237.4 251.5 241.8 232.7*2
Emissions per sales unit t-CO2
/100 million yen
26.9 27.1 28.7 27.3 26.7
Outside Japan

Scope of data collection: Production subsidiaries outside Japan, sales subsidiaries outside Japan (main sites)

  Unit Results
FY2008 FY2009 FY2010 FY2011 FY2012
Scope1 CO2 1000t-CO2 29.8 26.1 76.1 79.1 77.8*4
5 gases (CO2 equivalent) 1000t-CO2 0 0 0 0 0
Scope2 CO2 1000t-CO2 57.1 75.2 110.3 124.0 145.3*3
Total 1000t-CO2 86.9 101.4 186.4 203.1 223.1*3
Emissions per sales unit t-CO2
/100 million yen
7.5 8.9 17.5 20.0 21.2
  • *Inaccuracies have been identified in the fiscal 2011 data reported in the past, and corrections have been made with the reporting of fiscal 2012 data.
Japan / Outside Japan

Scope of data collection: Ricoh Company, Ltd. (production/non-production sites), production subsidiaries inside and outside Japan, non-production subsidiaries in Japan, and sales subsidiaries outside Japan (main sites)

  Unit Results
FY2008 FY2009 FY2010 FY2011 FY2012
Scope1 CO2 1000t-CO2 118.6 104.7 158.5 161.9 158.9*3
5 gases (CO2 equivalent) 1000t-CO2 28.2 23.1 22.9 21.4 18.5*1
Scope2 CO2 1000t-CO2 192.6 210.9 256.5 261.6 278.5*2
Total 1000t-CO2 339.4 338.7 437.9 444.9 455.8*2
Emissions per sales unit t-CO2
/100 million yen
16.2 16.8 22.6 23.4 23.7
  • *Inaccuracies have been identified in the fiscal 2011 data reported in the past, and corrections have been made with the reporting of fiscal 2012 data.

3. CO2 emissions in logistics by Ricoh Group

Scope of data collection: Ricoh Group

  Unit Results
FY2008 FY2009 FY2010 FY2011 FY2012
Domestic logistics 1000t-CO2 25.0 24.8 21.6 25.8 26.4
International logistics between business sites 1000t-CO2 239.7 193.8 292.1 444.6 297.7
Overseas logistics within the same area/country 1000t-CO2 - - - - 65.7
Total 1000t-CO2 264.7 218.6 313.7 470.4 389.8
Emissions per sales unit t-CO2
/100 million yen
12.7 10.8 16.2 24.7 20.3
  • *Domestic data is obtained by totaling actual transportation records regarding product delivery by production sites, product sales and collections.
  • *Overseas data is obtained by totaling actual records regarding international transportation between major sites and some transportation within the same area/country.
  • *Inaccuracies have been identified in the fiscal 2009, 2010 and 2011 data reported in the past, and corrections have been made with the reporting of fiscal 2012 data.

CO2 emissions during product use

Scope of data collection: Amount of CO2 emissions arising from the use of equipment sold during each fiscal year, calculated based on expected service life

  Unit Results
FY2008 FY2009 FY2010 FY2011 FY2012
CO2 1000t-CO2 - - 492.2 447.4 515.4
  • *The figure for FY2012 represents a significant increase from the previous year. This is attributable to the expanded scope of equipment surveyed that includes projectors, unified communication system and LED lighting, starting this fiscal year.
  • *Inaccuracies have been identified in the fiscal 2011 data reported in the past, and corrections have been made with the reporting of fiscal 2012 data.

Page Top