Intelligent Power Switch

Intelligent Power Switch

Intelligent power switch protects power lines. R5550K can detect two different over current thresholds and an under voltage error. When the R5550K detects over current, the switch turns off after the preset delay time. If an abnormal voltage is detected, the switch turns off after the preset delay time (10ms). After detecting the abnormal situation, the switch turns on again automatically if the cause of the error is removed.

Intelligent Power Switch Products Lineup

Product
Name
ON Resistance Supply
Current
Operating Voltage Range UVLO Detect
Voltage
Output
Current
Current Limit Threshold Output Current Limit Internal
FET
Typ. Typ. Min. Typ. Max. Min. Typ. Max.
R5550K001A 180mΩ  2.6µA  2.3V to 5.25V  1.9V  1A  300mA  460mA  624mA  1130mA  1470mA  1790mA  Pch 
Product
Name
Detector
Threshold
Current Limit/Under Voltage
Detection
Output Current Limit Protection Package Data
Sheet
(PDF)
Typ. Delay Time OFF Time ON Time Delay Time OFF Time ON Time
R5550K001A 0.5V 10ms  80ms  2.5ms  1.33ms  80ms  1.33ms  Auto Release DFN(PLP)1010-4F Download

*