R5435x Series

Li-ION/POLYMER 2/3-CELL PROTECTOR Second protection IC

Data Sheet
Data Sheet

R5435x Series are CMOS-based high voltage tolerant over-charge protection ICs for Li-ion/Li-polymer secondary battery. The R5435x can detect overcharge of 2-cell to 3-cell Li-ion/ Li-polymer batteries. The R5435x is consists of 3 voltage detectors, a voltage reference unit, an oscillator, a counter, a delay circuit, a logic circuit.

When the over-charge is detected, after the IC internally fixed delay time, the output of COUT becomes "H".

After detecting over-charge, when the cell voltage becomes lower than the over-charge released voltage, the over-charge state is released.

If all the cells voltages become equal or less than the shutdown detector threshold, all the circuits are halted and shut down, as a result, the consumption current of IC itself (Shutdown current) is extremely reduced.

By connect short 2 cells other than monitored cell, over-charge and released delay time can be shortened.

The output type is CMOS.

Manufactured with High Voltage Tolerant Process Absolute Maximum Rating 30V
Low supply current Cell voltage 3.9V, for 3-cell Typ. 3.0µA
High accuracy detector threshold Over-charge detector (Ta=25°C) ±20mV
(Ta=0 to 60°C) ±25mV
Variety of detector threshold Over-charge detector threshold 4.1V-4.55V step of 0.005V (VDET1n) (n=1, 2, 3)
Over-charge released voltage VDET1n-0V to VDET1n-0.4V step of 0.05V (VREL1n) (n=1, 2, 3)
MIN.3.95V
Setting of Output delay time Over-charge detector Output Delay options 2, 4, 6s (Built-in delay)
Shutdown Function When all the cell voltages become equal or less than shutdown detector threshold, the IC will be into shutdown mode and the consumption current of IC itself becomes extremely small. Even if one of the cells becomes equal or more than shutdown released voltage, the shutdown mode is released.
Shutdown detector threshold Typ. 3.5V±0.4V
Shutdown Release Hysteresis none
Shutdown current Max. 0.1µA
2/3 cell protection enabler By external wiring, 2 or 3-cell protection can be selected.
Over-charge released condition Released by voltage type
COUT output COUT: 4.7V regulator power supply CMOS output. Active "H"
Delay Time Shortening Function As a result of specified setting, the delay times are shortened, over-charge detector time is shortened from 2sec to 1/50, 4sec and 6sec to 1/80.
ex. VC2=VC3=VSS, the delay time for cell 1 is shortened. VC1=VC2, VC3=VSS, the delay time for cell 2 is shortened.
VC1=VC2=VC3, the delay time for cell 3 is shortened.
Small package TSOT-23-6, DFN(PLP)1616-6B
  • Power source for portable communication equipment.
  • Power source for electrical appliances such as PC.

DataSheet Package Info. Quality Assurance Data
R5435x Series DFN(PLP)1616-6B Reliability
TSOT-23-6 Reliability

All PDF files are less than 1MB unless otherwise stated.

  • Buy Products / Order Sample

Distributors

Ricoh semiconductor products are available at those dealers.

Information

Page Top